AeroCheck2 |
AeroCheck+ |
|
Probe |
Connectors |
12 Way Lemo 2b (Absolute, Bridge and Refection) and Connection Lemo 00 (for single element absolute probes) |
Simultaneous probe operation possible using Lemo 12 way and Lemo 00 |
Rotary |
600-3000 rpm - ETher Mercury Drive (ADR002), Hocking 33A100, Rohmann MR3, SR1 and SR2 Drive (special adapter needed) |
||
Frequency |
|
Single Freq. = 10Hz – 20MHz with range variable resolution |
Dual Freq. = 10Hz - 12.8MHz & Mix -18 to +18dB on output |
Gain |
Overall |
-18 to + 104dB, 0.1, 1 and 6dB steps (104dB maximum) 0dB or 12dB
0dB, 6dB and 10dB (0dB reference 1mW into 50 ohm). +/-100.0 dB |
|
Input Gain |
0dB or 12dB |
||
Drive |
0dB, 6dB and 10dB (0dB reference 1mW into 50 ohm) |
||
Max. X/Y Ratio |
+/-100.0 dB |
||
Phase |
Range |
0.0-359.9°, 0.1° steps
|
|
Auto Phase |
Allows phase angle to be automatically set to a pre set angle |
||
Filters |
Normal High Pass |
DC to 2kHz or Low Pass Filter, which ever is the lower in 1 Hz steps. Plus variable adaptive balance drift compensation 0.01 - 0.5 Hz (6 steps) |
|
Normal Low Pass |
1Hz to 2kHz or a quarter of the lowest test frequency, which ever is lower in 1 Hz steps. |
||
Balance |
Manual |
14 internal balance loads; 2.2μH, 5.0μH, 6.0μH, 6.5μH, 7.0μH, 7.5μH, 8.2μH, 12μH, 15μH, 18μH, 22μH, 30μH, 47μH, 82μH
|
|
Automatic |
Optimised balance load selection |
||
Alarms |
Box Sector Output |
Fully configurable, Freeze, Tone or Visual.
. |
|
Sector |
Fully configurable, Freeze, Tone or Visual |
||
Output |
Open collector transistor (32v dc at 10mA max) available on 12 way Lemo |
||
Display |
Type |
5.7” (145mm), 18 bit Colour, daylight readable |
|
Viewable Area |
115.2mm (Horizontal) x 86.4mm (Vertical) |
||
Resolution |
640 x 480 pixels
|
||
Flip |
Manual or automatic screen orientation change to enable left or right handed use |
||
Colour Schemes Configurable |
User configurable Dark, Bright and Black & White |
||
Screen
Display Modes |
Full Screen, Single, Dual Spot or Dual Pane with variable size and location and function e.g. MY, Timebase, Waterfall and Meter. |
||
Graticules |
Choice of Grid (4 sizes 5, 10, 15 and 20% FSH), Polar (4 sizes 5, 10, 15 and 20% FSH) or none |
||
Offset |
Spot Position: Y =-50 to +50, X =-65 to +65% |
||
Digital Spot Position Readout |
Display in X,Y or R,θ |
||
Summary |
Legacy Format |
||
Removable Data Storage |
Setup |
micro SD up to 32GB, holding over 10,000 settings |
|
Stored Screen Shots |
micro SD up to 32GB, holding over 10,000 screen shots |
||
Record/Replay |
Comprehensive Record Replay and Storage. Realtime recording of trace data and Replay on instruments and desktop PC up to 164 seconds |
||
Outputs |
PC Connectivity |
USB (Full PC remote control plus Real Time data) |
|
Digital Volt Free Alarm |
Available on Lemo 12 way, Open collector transistor (36v dc at 10mA max) |
||
VGA |
Full 15 way VGA output |
||
Languages |
|
English, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese, Turkish, Czech, Norwegian |
|
Verification Level |
|
The system includes on delivery a 2 year validity Verification Level 2 detailed functional check and calibration as per ISO 15548-1:2013 |
|
Power On Self Test |
|
The system performs a self test on start up of external ram, sd ram, accelerometer, Micro SD card, LCD screen buffer. |
|
Power |
External |
100-240 v 50-60Hz 30 Watts |
|
Battery |
Internal 7.2V nominal @ 3100mAh = 22.32 watch |
||
Running Time |
Up to 8 hours with a 2MHz Pencil Probe 30% Back Light and up to 6 hours with a Rotary Drive at 3000rpm 50% duty cycle |
||
Charging Time |
2.5 hrs. charge time - Simultaneous charge and operation possible |
||
Physical |
Weight |
1.2 kg, 2.7 lbs |
|
Size (w x h x d) |
237.5mm x 144mm x 52mm / 9.4” x 5.7” x 2.1” |
||
Material |
Aluminium alloy Mg Si 0.5 powder-coated |
||
Operating Temperature |
-20 to +60 °C
Storage for up to 12 months -20 to +35 °C Nominal +20 °C |
||
Storage Temperature |
Storage for up to 12 months -20 to +35 °C Nominal +20 °C |
||
IP Rating |
54 |
Conductivity Specification + version only |
||
Frequency |
One frequency only 60kHz standard (choice of 120, 240 and 480kHz) |
|
Resolution |
3 decimal points max |
|
Auto Resolution Mode AutoS = Legacy Instrument, Auto = SigmaCheck |
Acccuracy |
0.5%-10% IACS better than +/-0.05% IACS 10%-25% IACS better than +/-0.25% IACS 25%-60% IACS better than +/-0.5% IACS 60%-110% IACS better than +/-1% IACS Lift Off corrected to 1.0mm No temperature compensation All Errors at 90% Confidence Level |